When two racks are positioned side by side with centre distance 800mm, there will be storage for patch cord over length. Up to 4 meter over length of etch cable can be stored.
There is an integrated cable duct on top of etch rack. Patch cord crossing from one rack to the other is simple. No need for overhead mounted cable duct and no threading of patch cords. All passages are open.
Bending radius min 30mm is guaranteed. Surface treatment for good electrical conductivity. Grounding rail for 10 connections.

| ODF 1u A/D+S 8SC (4xSC duplex) | Part No: 5240/101 | |
|---|---|---|
| ODF 1u A/D+S 48SC (24xSC duplex) | Part No: /101 | |
| ODF 1u A/D+S | 0 | |
| (Front without outlets, only for splicing) | Part No: 5310/101 | |

Combined ODF and splicebox for mounting in 19" rack/cabinet or wall. Height 1u, Depth 300 mm. Detachable mounting ears are enclosed.
Application 1: Customer ODF in community networks. Application 2: Connection of nodes -uplink between nodes.
Possibility to enter the box with a 96-fibre cable, drop up to 48 fibres and exit with the same cable. Can also be use as a splice box. One 48 fibre cable can be spliced to a numerous of smaller sized.
Cable diameter 5-18 mm.
Accessories: Installation kit Part No: 5276 Bending Radius limiter, Part No: 5238 Cable entrance, optional left or right.

| ODF fixed 1u 8SC (4xSC duplex) | Part No: 5257/101 |
| ODF fixed 1u 24SC (12xSC duplex) | Part No: 5248/101 |
| ODF fixed 1u 48SC (24x SC duplex) | Part No: 5277/101 |

The outlet front is setback 30 mm from ODF mounting point. This gives larger space for a safe bending radius of the patch cord
Accessories: Installation kit Part No: 5276 Bending Radius limiter, Part No: 5238
ODF 1u Microduct 5 48-24 (24xSC duplex, fixture for 24 tubes diam.5mm) Part No: 5274/101 ODF 1u Microduct 4 48-24 (24xSC duplex, fixture for 24 tubes diam. 4mm) Part No: 5327/101

Height 1u, depth 280 mm for 19" rack/cabinet
The front outlet is extensible 200mm. Blowing and splicing of fibre is made with ODF mounted in rack.
All service is made from the front side. No free space between
additional ODF:s is needed. This gives high packing density.
More than 720 systems in one rack. With front outlet pulled out, the inner contacts as well as adaptors are accessible both from above and under service friendly
Complete with installation kit: splice holder (4 8 splices) and fibre holder Guiding of fibres inside the ODF guarantee min bending radius 30mm The outlet front is setback 30 mm from ODF mounting point. This gives larger space for a safe bending radius of the patch cord
The ODF is delivered in left mode, micro duct entrance from left. If a right mode is requested the extensible box can be moved rightwards after reassembling of the holder plate for micro ducts.
Accessories: Bending Radius limiter, Part No: 5238/01

| ODF 48. For 48 fibres (Holes for 24 SC duplex) | Part no. 5224/101 |
| ODF 72 LC/MTRJ. For 72 fibres. Front is marked 1-72 | |
| For adapters type LC quad or MTRJ-duplex, 18BOs | Part no. 5308/101 |
| ODF 96 LC/MTRJ. For 96 fibres. Front is marked 1-96 | Part no. 5309/101 |
| For adapters type LC quad or MTRJ-duplex, 24BOs |

ODF for loose tube or ribbon cable. Cable diameter 5-18mm Height 1u, depth 310mm, for 19" rack/cabinet. Cable entrance placed in corner, optional left or right -gives larger cable space. Complete with installation kit: splice holder for single and ribbon splices, fibre
holder and holder for fan-out sleeves. Guiding of fibres inside ODF guarantee min bending radius 30mm The outlet front can be pulled out 130 mm. Pulled out, the inner contacts, as well
as the adapters, are accessible from above and under -service friendly. The outlet front is setback 30 mm from ODF mounting point. This gives larger space for a safe bending radius of the patch cord
Accessories: Bending Radius limiter, Part No: 5238
ODF for loose tube or ribbon cable. Cable diameter 5-18mm Height 2u, depth 310mm, for 19" rack/cabinet. Cable entrance placed in corner, optional left or right -gives larger cable space. Complete with installation kit: splice holder for single and ribbon splices, fibre holder and holder for fan-out sleeves.

Guiding of fibres inside ODF guarantee min bending radius 30mm The outlet front can be pulled out 130 mm. Pulled out, the inner contacts, as well as the adapters, are accessible from above and under -service friendly.
The outlet front is setback 30 mm from ODF mounting point. This gives larger space for a safe bending radius of the patch cord
Accessories: Bending Radius limiter Part No: 5239


ODF for loose tube or ribbon type. Cable diameter 5-20 mm. Height 3u, Depth 310 mm, for 19" rack/cabinet. Cable entrance placed in corner, optional left or right -gives larger cable bending radius. Complete with installation kit: splice holder for single and ribbon splices, fibre
holder and holder for fan-out sleeves.
Guiding of fibres inside ODF guarantees min bending radius 30mm The adapters are devided in two outlet fronts. The front can be separately pulled out -easy installation and service.
The outlet front can be pulled out 130 mm. Pulled out, the inner contacts, as well as the adapters, are accessible from above and below -service friendly.
The outlet front is setback 30 mm from ODF mounting point. This gives large space for a safe bending radius of the patch cord
Accessories: Bending radius limiter Part No: 5239(2u), 1BO Bending radius limiter Part No: 5238(1u), 1BO


ODF loose tube or ribbon type. Cable diameter 520 mm. Height 4u, Depth 310 mm, for 19" rack/cabinet. Cable entrance placed in corner, optional left or right -gives larger cable bending radius. Complete with installation kit: splice holder for single and
ribbon splices, fibre holder and holder for fan-out sleeves.
Guiding of fibres inside ODF guarantees min bending radius 30mm The adapters are devided in two outlet fronts. The front can be separately pulled out -easy installation and service.
The outlet front can be pulled out 130 mm. Pulled out, the inner contacts, as well as the adapters, are accessible from above and under -service friendly.
The outlet front is setback 30 mm from ODF mounting point. This gives larger space for a safe bending radius of the patch cord
Accessory: Bending radius limiter, Part No: 5239, 2BOs.


Accessory: Bending Radius limiter, Part No:. 5238

| LM wall box 4(Holes for 2 SC duplex) | Part no. 5311 |
| HxWxD: 150x100x18mm | |
| LM Wallbox 8(Holes for 4 SC duplex) | Part no. 5297 |
| HxWxD:150x100x38mm |

Wall box with small outher dimensions and safe fibre handling
Guiding of fibres guarante min bending radius 30mm
The box is delivered complete with splice holders, 12 simplex or 4 ribbon splices can be handled. Splice shells with max length 45mm and adapters without ears is recommended
The box has 5 cable entrances, in each corner and one at the sink. Max cable diameter 11mm. Traditional cable, micro cable and micro ducts can me connected
The box is made from steel, painted with structure corral white colour. It has stand offs for wall mount.
Can be sealed